Three single loops enhance the biomechanical behavior of the transtibial pull-out technique for posterior meniscal root repair
2017
Purpose: To investigate the effect of applying an additional suture to enhance the biomechanical behavior of the suture–meniscus construct used during the transtibial pull- out repair technique. Methods: A total of 20 fresh-frozen porcine tibiae with intact medial menisci were used. In one half of all speci- mens (N = 10), two non-absorbable sutures were passed directly over the meniscal root from the tibia side of the meniscus to the femoral side (2SS). In other ten specimens, three sutures were passed over the meniscal root (3SS). All specimens were subjected to cyclic loading followed by load-to-failure testing. Displacement of the construct was recorded at 100, 500, and 1000 cycles. Fur…